Titan Pro Firmware

1.1.1.38707 36.6 MB 62 Downloads 1 Files
Download
or download free
[free_download_btn]

 

Change Log

1.1.1.38707
ISOC write failures are properly reported and retried
Harmonize power management settings for compatibility with trunk calibration and test tools
Correct user account privileges, add user sudo password

1.1.1.38106
Accumulated bug fix

1.0.1.36661
Changes in this version:
Extends compatibility with v11 predistortion files, so as to provide a 1.0 revert if needed for testing.
Fixes IFETEL_PART_90 omission in PS111 valid protocol check.
Compatible with new version of factory tools: Calibration Tools, Commissioning tool and new SD image

1.0.1.36352
Accumulated bug fix

1.0.1.36245
-This version includes a script change missing on some updates. This script change will also be in future releases.
- resolve NTP issue
- resolve Web interface issue

1.1.1.36159
Try to fix "reader.enable_isoc=0" not working problem.

1.0.1.36120
There were conflicts between arrive conditions from the following C2 commands:

tag_reporting_arrive_generation
no wait
tid
user
all
tag_security_v2_authentication_mode
v2 auth automatically added/removed
tag_security_password_authentication_enable
pw auth automatically added/removed
tag_security_tid_authentication_enable
tid auth automatically added/removed

New functionality in this version & moving forward, which we think is intended functionality:
no wait means no wait, no matter what read or auth opspecs are to be run
tid wait mean only tid is required, regardless of auth configuration
user data wait means only user data is required, regardless of auth configuration
note that if both tid and user data are enabled, tid is always read first
all means tid, user, and any auth configured through the tag.security namespace
Please let us know your thoughts on this matter as implemented in 36120 here.

1.0.1.35848
This version addresses:
License and keyring loading failure
Info events (event.info) having an extra terminator
Better instrumentation for MCU core faults

1.0.1.35753
This version addresses
VSWR performance
ECDH keyring key issues
Setting static IP address

1.0.1.35557
Please use the attached software together with the new Boolean variable “tag.writeback.ps111.verify“ which, when set to true, causes an immediate read after write.

1.0.1.35549
This version has a support level variable “tag.security.artesp.timeout" to set the security timeout from 20 to 1000 milliseconds, the default being 100.

1.0.1.35445
The previous build would activate the PTP (Precision Time Protocol) service even if it wasn’t configured to do so, which interacts poorly with NTP. This version only activates PTP if it’s enabled.

1.0.1.35438
Please use the attached SW to address these issues:
tid_authentic fail even though tid matches mask, firmware 35367
Mux Sequence Cannot Be Saved
Titan Pro Failsafe timer tracelog trigger

1.0.1.35418
This version corrects a logic bug in the tag security state logic.

1.0.1.35407
This version ensures that the ‘inauthentic’ status gets cleared in the event an initial TID read failed:

1.0.1.35335
This version is trying to resolve "Titan Pro v1 password authentication always report INAUTHENTIC"

1.0.1.35142
This version fixed the web interface 2.1 cannot show "current Profile" correctly issue.

1.0.1.35013
This version 35013 fixes a bug that can affect ISOC tag access opspecs.

1.0.1.34991
Added dio.out.set_mode
Fixed firmware updates from reader.upgrade_firmware() not respecting diag.bypass_build_type

1.0.1.34987
Fixes bug in Miller demodulator that could cause crashes or other unexpected behavior when running ROSpecs actions.

1.0.1.34730_rr (Web Interface 2.1)
Web interface updated to version 2.1

1.0.1.34236_rr (CU-1)
Major file system update
MUST update to CU-1 first if current firmware is older than 34236

[changelog]

Categories & Tags

Similar Downloads

No related download found!
 

Read This Carefully Before Downloading

 

Disclaimer

Except as expressly set forth above, STAR Systems International Pte. Ltd. makes no representation or warranty of any kind, express, implied or statutory, including but not limited to warranties of merchantability, fitness for a particular purpose, title or non-infringement, or warranties or obligations arising from a course of dealing, usage or trade practice. further, STAR Systems International Pte. Ltd. does not warrant that the firmware program/software is error free or that buyer will be able to operate the firmware program /software without problems or interruption.

Limitation of Liability

To the fullest extent not prohibited by law, in no event will STAR Systems International Pte. Ltd. or its affiliates or suppliers be liable for any loss of use, interruption of business, lost profits, or lost data, or indirect, special, hybrid, incidental or consequential damages of any kind regardless of the form of action, whether in contract, tort (including negligence), strict liability or otherwise, even if STAR Systems International Pte. Ltd. or its affiliate or supplier has been advised of the possibility of such damage, and whether or not any remedy provided should fail of its essential purpose. The total cumulative liability to customer, from all causes of action and all theories of liability, will be limited to and will not exceed the purchase price of the product paid by customer. In addition, STAR Systems International Pte. Ltd. shall not be liable for customer’s or any third party’s software, firmware, information, or memory data contained in, sorted on, or integrated with any product returned to STAR Systems International Pte. Ltd. whether under warranty or not.